Unenhanced computed tomography for non-invasive diagnosis of hepatic steatosis with low tube potential protocol
Original Article

Unenhanced computed tomography for non-invasive diagnosis of hepatic steatosis with low tube potential protocol

Yunjung Choi1^, Dong Kyun Kim1*^, Seo Yeon Youn1^, Hokun Kim1^, Joon-Il Choi1,2*^

1Department of Radiology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea; 2Catholic Cancer Research Institute, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea

Contributions: (I) Conception and design: JI Choi; (II) Administrative support: SY Youn, H Kim; (III) Provision of study materials or patients: Y Choi, DK Kim; (IV) Collection and assembly of data: Y Choi, DK Kim; (V) Data analysis and interpretation: DK Kim, JI Choi; (VI) Manuscript writing: All authors; (VII) Final approval of manuscript: All authors.

*These authors contributed equally to this work as co-corresponding authors.

^ORCID: Yunjung Choi, 0000-0003-0983-0441; Dong Kyun Kim, 0000-0003-3092-3810; Seo Yeon Youn, 0000-0002-7692-3413; Hokun Kim, 0000-0003-0884-7946; Joon-Il Choi, 0000-0003-0018-8712.

Correspondence to: Joon-Il Choi, MD. Department of Radiology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 06591, Republic of Korea. Email: dumkycji@gmail.com.

Background: Lowering kVp affects the image contrast and computed tomography (CT) attenuation values of low kVp CT is different from those of conventional 120-kVp scans. The purpose of this study is to determine the diagnostic performance and to establish the reference range of low-kVp unenhanced CT for the assessment of hepatic steatosis in liver transplantation donors using magnetic resonance (MR) spectroscopy as a reference standard.

Methods: This retrospective study included 165 potential donors (male:female =114:51, 36.5±12.0 years old) who underwent 100-kVp single-slice unenhanced CT scan and MR spectroscopy. The difference between hepatic and splenic attenuation (CTL-S) and liver-to-spleen attenuation ratio (CTL/S) were calculated. Reference standard was the fat signal fraction measured by MR spectroscopy. Limits of agreement between CT measurements and the reference standard were calculated. Areas under receiver operating characteristic curves (AUROCs) of CTL-S and CTL/S were compared for the diagnosis of moderate to severe steatosis. Cut-off values of CTL-S and CTL/S that provided a balance between sensitivity and specificity and the highest specificity using the lower limit of the reference range were calculated.

Results: Eighty-seven subjects had a non-steatotic liver. Sixty-one subjects had mild steatosis and 17 subjects had moderate to severe steatosis based on MR spectroscopy. CTL-S and CTL/S values were negatively correlated with the fat signal fraction (P<0.001) and limits of agreement were −8.4% to 8.4% for CTL-S and −9.6% to 9.6% for CTL/S. AUROCs of CTL-S and CTL/S for diagnosing moderate to severe steatosis were 0.956 and 0.957, respectively. Cut-off values of CTL-S and CTL/S for diagnosis of moderate to severe steatosis by the Youden index were −0.5 HU for CTL-S and 0.99 for CTL/S. Reference ranges of non-steatotic liver were −6.90 to 31.40 HU for CTL-S and 0.89 to 1.77 for CTL/S. Using −6.9 HU for CTL-S and 0.89 for CTL/S as cut-off values, the sensitivity and specificity for diagnosing moderate to severe steatosis were 70.59% and 90.54% (CTL-S) and 76.47% and 90.54% (CTL/S), respectively.

Conclusions: Measurements from a low-kVp unenhanced CT scan were negatively correlated with the degree of hepatic steatosis. Low-kVp unenhanced CT is a robust technique with reduced radiation exposure for diagnosing moderate to severe hepatic steatosis.

Keywords: Liver; steatosis; computed tomography (CT); magnetic resonance spectroscopy (MRS)


Submitted May 06, 2021. Accepted for publication Sep 18, 2021.

doi: 10.21037/qims-21-474


Introduction

Non-alcoholic fatty liver disease (NAFLD) is the most common liver parenchymal disease and an important health issue because NAFLD is associated not only with liver diseases such as non-alcoholic steatohepatitis, cirrhosis, and hepatocellular carcinoma, but also various systemic problems including cardiovascular and metabolic disease (1-5). Furthermore, hepatic steatosis, especially macrovesicular hepatic steatosis, affects liver transplantation outcomes (6,7). In living donor liver transplantation (LDLT), the degree of hepatic steatosis affects both recipient outcomes and donor safety because hepatic steatosis increases the incidence of graft failure in recipients and impairs hepatic regeneration in donors (8-10).

Although liver biopsy is regarded to be the gold standard method for establishing a diagnosis of hepatic steatosis, various imaging methods and biochemical evaluations are widely used to evaluate hepatic steatosis. Magnetic resonance imaging (MRI) techniques including two-point Dixon dual echo imaging, magnetic resonance spectroscopy (MRS) and MRI proton density fat fraction (MRI-PDFF) have diagnostic value similar to that of histologic examination for assessment of hepatic steatosis (11-16). Meanwhile dual echo imaging is mainly a qualitative tool, MRS and MRI-PDFF are quantitative tools.

Previous studies reported that unenhanced computed tomography (CT) had a high specificity for diagnosing macrovesicular steatosis 30% or greater and could help avoid unnecessary biopsy in potential LDLT donors (7,17-20). However, previous research results were derived from unenhanced CT scans obtained at 120-kVp in the early 2000s. Since the 2010s, tube potential selection techniques have been widely adopted to reduce radiation exposure, and low-kVp images have become increasingly popular. As a consequence, abdominal CT scans using 100-kVp or 80-kVp are generally obtained, especially in Asian countries where patients tend to be small in size. In our institution, abdominal CT images for LDLT donors are usually obtained at 100-kVp to reduce radiation exposure. The unenhanced scan is obtained as a single slice image covering the spleen and liver to further reduce radiation exposure. Lowering kVp affects the image contrast and CT attenuation values of low kVp-CT is different from those of conventional 120-kVp scans. To the best of our knowledge, no prior study has evaluated the diagnostic performance or reference range of low-kVp CT attenuation values for evaluating hepatic steatosis.

Therefore, our aim in the current study was to investigate whether CT indices measured on a single slice unenhanced image obtained at a low-kVp were different from those obtained at 120-kVp using MRS as the standard of reference.

We present the following article in accordance with the STARD reporting checklist (available at https://dx.doi.org/10.21037/qims-21-474).


Methods

Study population

The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by the institutional review board of the Catholic University of Korea (No. KC21RASI0263) and individual consent for this retrospective analysis was waived. This was an exploratory research, and the comparison of diagnostic performance of low-kVp CT to full dose CT was not the purpose of the study. Therefore, we did not perform power analysis. The institutional database was searched for liver donor protocol CT for LDLT between January 2014 and May 2020.

Inclusion criteria for this study were as follows: (I) potential liver donor for living-donor liver transplantation; (II) subject underwent liver donor protocol CT including low-kVp (100-kVp) single-slice unenhanced CT covering the part of liver and spleen, and (III) the subject underwent MRS to evaluate hepatic steatosis within 7 days of liver CT examination. Exclusion criteria were as follows: (I) spleen not covered by low-kVp single-slice unenhanced CT, and (II) poor image quality of the unenhanced CT scan due to severe motion artifacts. A total of 249 consecutive, potential donors for LDLT underwent liver CT and/or MRI for pre-operative evaluation. Among them, 84 donor candidates were excluded from the study because a low-kVp (100-kVp) single-slice unenhanced CT scan was not taken (n=60), the spleen was not included in the single slice unenhanced CT scan (n=12), or MRS was not performed (n=12). The remaining 165 donor candidates were enrolled in this study (male:female =114:51, mean age 36.5±12.0 years) (Figure 1).

Figure 1 Diagram showing donor candidate enrollment. LDLT, living donor liver transplantation; CT, computed tomography; MRS, magnetic resonance spectroscopy.

Image acquisition techniques

Liver donor protocol CT scans were performed using a multi-detector low (64 channels or higher) CT scanner (Siemens SOMATOM definition AS+, Siemens Sensation 64, Siemens SOMATOM Force, or Siemens SOMATOM definition Edge, Siemens Healthineers, Erlangen, Germany) in all subjects. A single-slice low-kVp unenhanced scan covering the liver and spleen in addition to early arterial phase and portal venous phase images were obtained. Scan and reconstruction parameters for low-kVp unenhanced CT with a single slice were beam collimation of 128 mm × 0.6 mm, beam pitch of 1, gantry rotation time of 0.5 seconds, tube voltage of 100-kVp, and tube current of 20 mAs. To assess CT radiation dose, the dose length product (DLP) was calculated as 0.67 mGy·cm.

In all enrolled subjects, unenhanced liver MRI [axial T2-weighted image with fast spin echo and single-shot half-Fourier turbo spin echo, axial in-and-opposed phase T1 gradient recalled echo (GRE) images], 2D/3D magnetic resonance cholangiopancreatography to evaluate bile duct anatomy, and multiecho MRS to evaluate hepatic steatosis were performed. MRI was performed using one of two 3-Tesla (3T) scanners (Siemens Verio or Siemens MAGNETOM Vida, Siemens Healthineers, Erlangen, Germany). MRS was conducted using single-voxel technique called HISTO with stimulated echo acquisition mode (STEAM). A 3×3×3 cm3 voxel was placed in the hepatic parenchyma of the right hemiliver to avoid hepatic vessels, bile ducts, or focal hepatic lesions. During a single 15 second breath hold, five STEAM spectra were generated at multiple echo times (TEs) of 12, 24, 36, 48, and 72 ms. We used a long repetition time (TR) of 3,000 ms to minimize T1 weighting and high-speed T2 correction to prevent over-evaluating proton density fat fraction (21). The fat signal fraction and R2 water value can be calculated using this approach (Figure 2). In this study, we adopted fat signal fractions of 4.14% and 15.72% to classify any degree of hepatic steatosis (macrovesicular steatosis of less than 5% at histology) and moderate to severe hepatic steatosis (at least 30% macrovesicular steatosis at histology), respectively. These cut-off values of the fat signal fraction were based on the results of a previous study that used 3T multiecho MRS with similar techniques (22). We adopted MRS as the reference standard because (I) liver biopsy was performed in only part of the subjects and (II) multiecho MRS was reported to be closely correlated to pathology results for evaluating hepatic steatosis (13-15).

Figure 2 Magnetic resonance spectroscopy to measure the fat signal fraction. (A) A 3×3×3 cm3 voxel was located in the hepatic parenchyma of the right hemiliver to avoid hepatic vessels; (B) upper color bar shows the T2-corrected fat signal fraction (4.79% in this case). Lower color bar is for R2 water to evaluate iron deposition.

Data analysis

For each candidate, hepatic attenuation (L) and splenic attenuation (S) were measured in a low-kVp, single-slice unenhanced scan. L was measured as the average of the attenuation values of two regions of interest (ROIs) in Hounsfield unit (HU). ROIs were placed in two different segments in the right hemiliver. S was measured as the average of measurements in HU at two different ROIs in the spleen, regardless of underlying spleen anatomy (Figure 3). A senior resident of radiology department drew the ROIs and he/she was blinded to the clinical information and results of MRS or pathological examination for hepatic steatosis. Two different liver attenuation indices, the difference between hepatic and splenic attenuation (CTL-S) and the liver-to-spleen attenuation ratio (CTL/S) were calculated to quantify the degree of hepatic steatosis (17). For the evaluation of reproducibility of ROI measurement, a junior resident drew the ROIs again and we compared the mean values of attenuation indices to first measurement. We used first measurement by a senior resident for further analyses.

Figure 3 CT attenuation measurement on a low-kVp, single-slice unenhanced CT scan. Liver parenchyma attenuation was measured in two regions of interest (ROIs) of the right hemiliver. An ROI was placed in two different segments. To measure spleen attenuation, two ROI were placed in the spleen, regardless of the anatomical part of the spleen. Liver and spleen attenuation values in the two ROIs were averaged. CT, computed tomography; SD, standard deviation.

Linear regression analyses were performed between the two liver attenuation indices derived from CT measurements and the fat signal fraction derived from MRS to derive regression equations. Furthermore, limits of agreement between steatosis estimated by the regression equation and the fat signal fraction estimated by MRS were calculated for both CT attenuation indices using Bland-Altman plots. To compare the diagnostic performance of the two CT attenuation indices for the diagnosis of subjects with moderate to severe hepatic steatosis, receiver operating characteristic (ROC) analyses were performed and the areas under the ROC curves (AUROCs) and their 95% confidence intervals (CIs) were calculated and compared for both CT attenuation indices.

CTL-S and CTL/S cut-off values were used to diagnose moderate to severe hepatic steatosis to (I) provide a balance between sensitivity and specificity calculated by the Youden index and (II) the determine the highest specificity based on the lower limit of the reference range as determined by the Clinical and Laboratory Standards Institute (CLSI) guideline C28-A3. Cut-off values to balance sensitivity and specificity were calculated by choosing the value that was nearest to the left corner of the ROC curve to minimize false positives and negatives. Using these cut-off values, sensitivity, specificity, and 95% CIs were calculated and compared between the two CT attenuation indices. A reference range was also calculated using the method published in CLSI guideline C28-A3 to determine reference intervals of quantitative clinical laboratory tests (18). CLSI guideline C28-A3 is a guideline for the reference interval, i.e., values for healthy population, of medical assays and the lower and upper limits of the reference range were estimated as the 2.5% and 97.5%, respectively of the distribution in the reference population. This guideline is the most widely-used source of reference in this area and adopted by the statistical software packages. Calculation of the cut-off values based on the lower limit of the reference range by the CLSI guideline C28-A3 has two advantages: (I) to maximize specificity (97.5%, theoretically) and (II) to reduce the influence of the subject population because ROC based cut-off values can be heavily influenced by the distribution of the severity of steatosis in the study population (23). We also checked the normality of values of each CT index using the Shapiro-Wilks test because CLSI guidelines recommend that the reference population follow a Gaussian distribution. Using these cut-off values, we calculated and compared sensitivity and specificity for any degree of steatosis (≥4.14% of the fat signal fraction) and moderate to severe steatosis (≥15.72% of the fat signal fraction) using both CT attenuation indices.

To evaluate the reproducibility of ROI measurement, Lin’s concordance correlation coefficient was calculated. The following classification was used for the level of agreement by concordance correlation coefficient: <0.90, poor; ≥0.90, <0.95, moderate; ≥0.95, <0.99, substantial; ≥0.99, almost perfect agreement. To compare sensitivity and specificity, we used McNemar’s test. AUROCs were compared by DeLong’s method. IBM SPSS 24.0 for Windows (International Business Machines Corporation, New York, NY) and MedCalc 19.5.3 (MedCalc Software, Mariakerke, Belgium) were used for all statistical analyses. P<0.05 was considered to indicate statistical significance.


Results

On MRS, the fat fraction signal ranged from 0.40% to 33.75% (mean 6.59%±6.90%, median 3.73%) in the 165 donor candidates. Eighty-seven donor candidates (52.7%, 87/165) had a non-steatotic liver (<4.14% of the fat signal fraction), 61 donor candidates (37.0%, 61/165) had mild steatosis (≥4.14%, <15.72% of the fat signal fraction), and 17 donor candidates (10.3%, 17/165) had moderate to severe steatosis (≥15.72% of the fat signal fraction).

Lin’s concordance correlation coefficients for liver attenuation, spleen attenuation, L-S and L/S were 0.956, 0.905, 0.936 and 0.931, respectively and the reproducibility of ROI measurement was moderate to substantial.

In linear regression analyses, fat signal fraction and CT attenuation indices were negatively correlated (rho =−0.603, P<0.001 for CTL-S and rho =−0.423, P<0.001 for CTL/S, rho is Spearman’s correlation coefficient). Linear regression equations for fat signal fractions were (−0.451 × CTL-S) + 8.574 for CTL-S and (−18.310 × CTL/S) + 26.685 for CTL/S (Figure 4). Limits of agreement between the fat signal fraction and values estimated from the regression equations were −8.4% to 8.4% for CTL-S and −9.6% to 9.6% for CTL/S.

Figure 4 Scatter plots showing the results of linear regression analyses. (A) Scatterplots showing the results of linear regression analyses between the fat signal fraction and CTL-S (the difference between hepatic and splenic attenuation). Linear lines are best-fit lines of the linear regression equations; (B) scatterplots showing the results of linear regression analyses between the fat signal fraction and CTL/S (the liver-to-splenic attenuation ratio). Linear lines are best-fit lines of the linear regression equations. CT, computed tomography.

AUROCs of CTL-S and CTL/S for diagnosing moderate to severe steatosis were 0.956 (95% CI: 0.912–0.982) and 0.957 (95% CI: 0.914–0.986), respectively, with no significant difference (P=0.6314) (Figure 5). Cut-off values of CTL-S and CTL/S for diagnosis of moderate to severe hepatic steatosis by the Youden index were −0.5 HU and 0.99, respectively. With these cut-off values, the sensitivity and specificity of CTL-S and CTL/S for diagnosing moderate to severe hepatic steatosis were the same: 100.0% sensitivity and 84.46% specificity (Table 1).

Figure 5 Receiver operating characteristics (ROC) curves for diagnosing moderate to severe hepatic steatosis (15.72% of the fat signal fraction on magnetic resonance spectroscopy). (A) ROC curves for diagnosing moderate to severe hepatic steatosis using CTL-S (the difference between hepatic and splenic attenuation). Dots of each figure were the cut-off values by the Youden index; (B) ROC curves for diagnosing moderate to severe hepatic steatosis using CTL/S (the liver-to-splenic attenuation ratio). Dots of each figure were the cut-off values by the Youden index. The areas under the ROC curves of the two CT indices were not significantly different (P=0.6314). AUC, area under the ROC curves; CT, computed tomography; HU, Hounsfield unit.

Table 1

Sensitivity, specificity, and positive and negative predictive values of CTL-S and CTL/S for diagnosing moderate to severe hepatic steatosis using cut-off values based on the Youden index

Variables CTL-S CTL/S P values
Cut-off values −0.5 HU 0.99
Sensitivity (%) 100.00 (80.49–100.00) 100.00 (80.49–100.00) 1.000*
Specificity (%) 84.46 (77.60–89.89) 84.46 (77.60–89.89) 1.000*
Positive predictive value (%) 42.50 (33.67–51.83) 42.50 (33.67–51.83) 1.000#
Negative predictive value (%) 100.00 100.00 1.000#

*, P values calculated using the McNemar’s test; #, P values calculated using the Fisher’s exact test. Numbers in parentheses are 95% confidence intervals. CTL-S: difference between liver and spleen attenuation on a low-kVp, single-slice unenhanced CT scan; CTL/S: ratio of liver and spleen attenuation on a low-kVp, single-slice unenhanced CT scan. CT, computed tomography.

Reference ranges of CTL-S and CTL/S of donor candidates with non-steatotic liver were −6.90 to 31.40 HU (mean 10.02±7.24 HU, median 10.00 HU) and 0.89 to 1.77 (mean 1.21±0.17, median 1.19), respectively. We adopted the non-parametric percentile method of CLSI C28-A3 because the Shapiro-Wilks test rejected the normality of CT indices of donor candidates with non-steatotic liver (P=0.0016 for CTL-S and P<0.001 for CTL/S, respectively). Using −6.90 HU for CTL-S and 0.89 for CTL/S as cut-off values, sensitivity and specificity of CTL-S for any degree of hepatic steatosis were 29.49% and 97.70%, respectively, while sensitivity and specificity of CTL/S were 30.77% and 97.70%, respectively. Using these same cut-off values, sensitivity and specificity for diagnosing moderate or severe steatosis were 70.59% and 90.54% for CTL-S, respectively, and 76.47% and 90.54% for CTL/S, respectively (Table 2). There were no adverse events related to CT scans or MRS.

Table 2

Sensitivity and specificity of CTL-S and CTL/S for diagnosing hepatic steatosis using cut-off values based on the lower limit of the reference range determined by CLSI guideline C28-A3

Variables CTL-S CTL/S P values
Cut-off values −6.9 HU 0.89
Any degree of hepatic steatosis
   Sensitivity (%) 29.49 (19.70–40.89) 30.77 (20.81–42.24) 1.000
   Specificity (%) 97.70 (91.94–99.72) 97.70 (91.94–99.72) 1.000
Moderate to severe degree hepatic steatosis
   Sensitivity (%) 70.59 (44.0–89.7) 76.47 (50.1–93.2) 1.000
   Specificity (%) 90.54 (84.6–94.7) 90.54 (84.6–94.7) 1.000

P values were calculated using McNemar’s test. Numbers in parentheses are 95% confidence intervals. CTL-S: difference between liver and spleen attenuation on a low-kVp, single-slice unenhanced CT scan; CTL/S: ratio of liver and spleen attenuation on a low-kVp, single-slice unenhanced CT scan; CLSI guideline C28-A3: the Clinical and Laboratory Standards Institute guideline for reference interval. CT, computed tomography; HU, Hounsfield unit.


Discussion

Although liver biopsy provides a definitive diagnosis of hepatic steatosis and is therefore considered the gold standard method, it is an invasive method that may result in complications. Furthermore, sampling bias cannot be avoided because only a small amount of tissue can be obtained by biopsy and examined by pathological evaluation, and pathologist subjectivity may influence the diagnosis (14-18). Imaging examinations such as ultrasonography, CT, and MRI are non-invasive and useful tools for diagnosing hepatic steatosis. Although MRI is the most accurate of these imaging modalities, unenhanced CT scans can be used for reliable qualitative diagnosis of macrovesicular steatosis of 30% or greater (7,17,18). However, CT exposes patients and healthy individuals such as liver transplantation donor candidates to radiation. Acquiring CT images at a low-kVp could be a way to reduce the radiation exposure of potential donors who are usually young and therefore more radiosensitive and have longer life expectancies (24-27). Reducing the tube potential from 120 to 100 kVp can reduce radiation exposure by about one third (28,29). In contrast to tube current (mAs), a decrease in tube potential (kVp) not only affects radiation exposure and noise levels, but also image contrast because X-ray photons with higher energy can travel though the body without attenuation more easily than photons with lower energy potential. Lower proportion of Compton scattering compared to the photoelectric effect in X-ray photons of lower energy is another reason for a change in tissue contrast (30,31). Therefore, CT attenuation values from low-kVp CT scans are different from those of 120-kVp CT scans and the reference range for CT attenuation values to evaluate hepatic steatosis in CT images obtained at a low-kVp may be different from the existing reference range for conventional 120-kVp images.

In our study, the fat signal fraction was negatively correlated with MRS and CT attenuation indices. Both CTL-S and CTL/S provided high diagnostic performance for moderate to severe hepatic steatosis, with no significant difference between the two CT indices. Using a CTL-S cut-off value of −0.5 HU and a CTL/S cut-off value of 0.99 based on the Youden index to achieve a balance between sensitivity and specificity, both indices had 100% sensitivity and 84.46% specificity for diagnosing moderate to severe steatosis. When cut-off values of 6.9 HU and 0.89 were used for CTL-S and CTL/S, respectively, lower sensitivity (70.59–76.47%) but higher specificity (90.54%) were achieved compared to Youden index cut-off values.

Cut-off values of the Youden index reported in the previous study using 120-kVp CT scans were −7 HU for CTL-S and 0.9 for CTL/S (17). In that study, the sensitivities and specificities for diagnosing moderate to severe fatty liver were 82% and 100% for both CTL-S and CTL/S, respectively, representing a lower sensitivity and higher specificity than those estimated in our study. In another previous study using 120-kVp scans, the sensitivities for diagnosing all degree steatosis and moderate to severe steatosis were 18.6% and 67%, respectively, using a reference range cut-off value of 1 HU for CTL-S (18). Reference range of CTL-S in that study was 1 to 18 HU and much narrower than that in our study, −6.90 to 31.40 HU, and the standard deviation of that study (4.2 HU) was much smaller than that in our study (7.24 HU). We speculate that the wider range and greater standard deviation in our study than the previous study were due to the noisier images from low-kVp CT scans in our study and non-parametric characteristics of results of our study. Because of the lower cut-off value of CTL-S in our study (−6.9 HU compared to 1 HU), sensitivity for any degree steatosis was higher in this study than that in the previous study using 120-kVp, but the sensitivity for moderate to severe steatosis was similar (70.59% vs. 67%, respectively). When using a cut-off value of −6.9 HU for CTL-S, our non-enhanced low-kVp CT protocol showed similar to superior diagnostic performance to that of 120-kVp CT. Our low-kVp protocol can significantly reduce radiation exposure while allowing accurate diagnosis of hepatic steatosis. Furthermore, we only acquired a single slice unenhanced image covering both the liver and spleen to evaluate steatosis, which can minimize the radiation exposure of potential liver donors for LDLT.

In this study, we adopted multiecho MRS rather than liver biopsy as the reference standard. We thought this to be a reasonable strategy because multiecho MRS and MRI-PDFF have been demonstrated to be closely correlated to pathology results for evaluating hepatic steatosis and have been used as reference standards in recent clinical trials (13-15). Furthermore, this allowed us to avoid sampling errors and inter-observer variability, which are limitations of liver biopsy. We adopted cut-off values of the fat signal fraction for all degrees of steatosis (≥4.14%) and moderate to severe steatosis (≥15.72%) based on a study by Runge et al. (22) who used MRS with 3T MRI units. Also, other studies have reported similar cut-off values of the fat signal fraction for the diagnosis of hepatic steatosis in multiecho MRS and MRI-PDFF (12,32-35). Our MRI protocol includes in- and opposed-phase dual echo GRE technique and this also could be used for the quantification of hepatic fat deposition. However, dual echo imaging is mainly a qualitative tool and the measurement is less accurate than multiecho MRS (36). Also, cut-off values for the degree of steatosis were not reported for dual echo imaging. Therefore, we adopted MRS as a standard reference.

There are several limitations to our study. First, we included mainly young and healthy adults because all of these individuals were potential candidates for LDLT. Therefore, only 10.3% of enrolled subjects had moderate to severe hepatic steatosis. To overcome this limitation, we used a reference range to calculate the optimal cut-off value to maximize specificity. Second, although CT attenuation values are not influenced by ethnic group, all subjects in our study were Asian adults. Furthermore, our data were collected from a single institute and therefore, further validation is mandatory to generalize our results. Third, we could not compare CT indices calculated from standard tube potential (120-kVp) and low-kVp (100-kVp) scans directly because we only acquired a single slice image using low kVp. However, we felt that it would be unethical to acquire CT images using both conventional and low-kVp in the same subjects for research purposes only, especially young and healthy subjects.

In conclusion, we found that CT indices measured from a low-kVp, single-slice unenhanced CT scan were negatively correlated with the degree of hepatic steatosis and provided high diagnostic performance for diagnosis of hepatic steatosis. Diagnostic performance of CTL-S and CTL/S were similar. CT indices from our low-kVp, single-slice unenhanced CT protocol were robust for diagnosing moderate to severe hepatic steatosis and can help prevent unnecessary biopsies and minimize radiation exposure.


Acknowledgments

Funding: This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. 2019R1F1A1060566). This work was also supported by the Technology Innovation Program (No. 20011856) funded By the Ministry of Trade, Industry & Energy (MOTIE, Korea).


Footnote

Reporting Checklist: The authors have completed the STARD reporting checklist. Available at https://dx.doi.org/10.21037/qims-21-474

Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://dx.doi.org/10.21037/qims-21-474). JIC reports that he received grants from Guerbet Koreaand Samsung Medison. The other authors have no conflicts of interest to declare.

Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by the institutional review board of the Catholic University of Korea (No. KC21RASI0263) and individual consent for this retrospective analysis was waived.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.


References

  1. Boyce CJ, Pickhardt PJ, Kim DH, Taylor AJ, Winter TC, Bruce RJ, Lindstrom MJ, Hinshaw JL. Hepatic steatosis (fatty liver disease) in asymptomatic adults identified by unenhanced low-dose CT. AJR Am J Roentgenol 2010;194:623-8. [Crossref] [PubMed]
  2. Li J, Zou B, Yeo YH, Feng Y, Xie X, Lee DH, et al. Prevalence, incidence, and outcome of non-alcoholic fatty liver disease in Asia, 1999-2019: a systematic review and meta-analysis. Lancet Gastroenterol Hepatol 2019;4:389-98. [Crossref] [PubMed]
  3. Younossi ZM, Koenig AB, Abdelatif D, Fazel Y, Henry L, Wymer M. Global epidemiology of nonalcoholic fatty liver disease-Meta-analytic assessment of prevalence, incidence, and outcomes. Hepatology 2016;64:73-84. [Crossref] [PubMed]
  4. Eslam M, Newsome PN, Sarin SK, Anstee QM, Targher G, Romero-Gomez M, et al. A new definition for metabolic dysfunction-associated fatty liver disease: An international expert consensus statement. J Hepatol 2020;73:202-9. [Crossref] [PubMed]
  5. Pickhardt PJ, Jee Y, O'Connor SD, del Rio AM. Visceral adiposity and hepatic steatosis at abdominal CT: association with the metabolic syndrome. AJR Am J Roentgenol 2012;198:1100-7. [Crossref] [PubMed]
  6. Chen YS, Cheng YF, De Villa VH, Wang CC, Lin CC, Huang TL, Jawan B, Chen CL. Evaluation of living liver donors. Transplantation 2003;75:S16-9. [Crossref] [PubMed]
  7. Pickhardt PJ, Park SH, Hahn L, Lee SG, Bae KT, Yu ES. Specificity of unenhanced CT for non-invasive diagnosis of hepatic steatosis: implications for the investigation of the natural history of incidental steatosis. Eur Radiol 2012;22:1075-82. [Crossref] [PubMed]
  8. Meng H, Yang J, Yan L. Donor Safety in Adult-Adult Living Donor Liver Transplantation: A Single-Center Experience of 356 Cases. Med Sci Monit 2016;22:1623-9. [Crossref] [PubMed]
  9. Veteläinen R, van Vliet A, Gouma DJ, van Gulik TM. Steatosis as a risk factor in liver surgery. Ann Surg 2007;245:20-30. [Crossref] [PubMed]
  10. Lee JY, Kim KM, Lee SG, Yu E, Lim YS, Lee HC, Chung YH, Lee YS, Suh DJ. Prevalence and risk factors of non-alcoholic fatty liver disease in potential living liver donors in Korea: a review of 589 consecutive liver biopsies in a single center. J Hepatol 2007;47:239-44. [Crossref] [PubMed]
  11. Idilman IS, Aniktar H, Idilman R, Kabacam G, Savas B, Elhan A, Celik A, Bahar K, Karcaaltincaba M. Hepatic steatosis: quantification by proton density fat fraction with MR imaging versus liver biopsy. Radiology 2013;267:767-75. [Crossref] [PubMed]
  12. Middleton MS, Heba ER, Hooker CA, Bashir MR, Fowler KJ, Sandrasegaran K, Brunt EM, Kleiner DE, Doo E, Van Natta ML, Lavine JE, Neuschwander-Tetri BA, Sanyal A, Loomba R, Sirlin CBNASH Clinical Research Network. Agreement Between Magnetic Resonance Imaging Proton Density Fat Fraction Measurements and Pathologist-Assigned Steatosis Grades of Liver Biopsies From Adults With Nonalcoholic Steatohepatitis. Gastroenterology 2017;153:753-61. [Crossref] [PubMed]
  13. Boudinaud C, Abergel A, Joubert-Zakeyh J, Fontarensky M, Pereira B, Chauveau B, Garcier JM, Chabrot P, Boyer L, Magnin B. Quantification of steatosis in alcoholic and nonalcoholic fatty liver disease: Evaluation of four MR techniques versus biopsy. Eur J Radiol 2019;118:169-74. [Crossref] [PubMed]
  14. Caussy C, Reeder SB, Sirlin CB, Loomba R. Noninvasive, Quantitative Assessment of Liver Fat by MRI-PDFF as an Endpoint in NASH Trials. Hepatology 2018;68:763-72. [Crossref] [PubMed]
  15. Noureddin M, Lam J, Peterson MR, Middleton M, Hamilton G, Le TA, Bettencourt R, Changchien C, Brenner DA, Sirlin C, Loomba R. Utility of magnetic resonance imaging versus histology for quantifying changes in liver fat in nonalcoholic fatty liver disease trials. Hepatology 2013;58:1930-40. [Crossref] [PubMed]
  16. van Werven JR, Marsman HA, Nederveen AJ, Smits NJ, ten Kate FJ, van Gulik TM, Stoker J. Assessment of hepatic steatosis in patients undergoing liver resection: comparison of US, CT, T1-weighted dual-echo MR imaging, and point-resolved 1H MR spectroscopy. Radiology 2010;256:159-68. [Crossref] [PubMed]
  17. Park SH, Kim PN, Kim KW, Lee SW, Yoon SE, Park SW, Ha HK, Lee MG, Hwang S, Lee SG, Yu ES, Cho EY. Macrovesicular hepatic steatosis in living liver donors: use of CT for quantitative and qualitative assessment. Radiology 2006;239:105-12. [Crossref] [PubMed]
  18. Park YS, Park SH, Lee SS, Kim DY, Shin YM, Lee W, Lee SG, Yu ES. Biopsy-proven nonsteatotic liver in adults: estimation of reference range for difference in attenuation between the liver and the spleen at nonenhanced CT. Radiology 2011;258:760-6. [Crossref] [PubMed]
  19. Fritz GA, Schoellnast H, Deutschmann HA, Wiltgen M, Brader P, Berghold A, Groell R. Density histogram analysis of unenhanced hepatic computed tomography in patients with diffuse liver diseases. J Comput Assist Tomogr 2006;30:201-5. [Crossref] [PubMed]
  20. Limanond P, Raman SS, Lassman C, Sayre J, Ghobrial RM, Busuttil RW, Saab S, Lu DS. Macrovesicular hepatic steatosis in living related liver donors: correlation between CT and histologic findings. Radiology 2004;230:276-80. [Crossref] [PubMed]
  21. Bydder M, Yokoo T, Hamilton G, Middleton MS, Chavez AD, Schwimmer JB, Lavine JE, Sirlin CB. Relaxation effects in the quantification of fat using gradient echo imaging. Magn Reson Imaging 2008;26:347-59. [Crossref] [PubMed]
  22. Runge JH, Smits LP, Verheij J, Depla A, Kuiken SD, Baak BC, Nederveen AJ, Beuers U, Stoker J MR. Spectroscopy-derived Proton Density Fat Fraction Is Superior to Controlled Attenuation Parameter for Detecting and Grading Hepatic Steatosis. Radiology 2018;286:547-56. [Crossref] [PubMed]
  23. Weinstein S, Obuchowski NA, Lieber ML. Clinical evaluation of diagnostic tests. AJR Am J Roentgenol 2005;184:14-9. [Crossref] [PubMed]
  24. Guimarães LS, Fletcher JG, Harmsen WS, Yu L, Siddiki H, Melton Z, Huprich JE, Hough D, Hartman R, McCollough CH. Appropriate patient selection at abdominal dual-energy CT using 80 kV: relationship between patient size, image noise, and image quality. Radiology 2010;257:732-42. [Crossref] [PubMed]
  25. Funama Y, Awai K, Nakayama Y, Kakei K, Nagasue N, Shimamura M, Sato N, Sultana S, Morishita S, Yamashita Y. Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 2005;237:905-10. [Crossref] [PubMed]
  26. Royal HD. Effects of low level radiation-what's new? Semin Nucl Med 2008;38:392-402. [Crossref] [PubMed]
  27. Seyal AR, Arslanoglu A, Abboud SF, Sahin A, Horowitz JM, Yaghmai V. CT of the Abdomen with Reduced Tube Voltage in Adults: A Practical Approach. Radiographics 2015;35:1922-39. [Crossref] [PubMed]
  28. Raman SP, Johnson PT, Deshmukh S, Mahesh M, Grant KL, Fishman EK. CT dose reduction applications: available tools on the latest generation of CT scanners. J Am Coll Radiol 2013;10:37-41. [Crossref] [PubMed]
  29. Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF. Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 2004;231:169-74. [Crossref] [PubMed]
  30. Martin C. The importance of radiation quality for optimisation in radiology. Biomed Imaging Interv J 2007;3:e38. [Crossref] [PubMed]
  31. Seibert JA. Tradeoffs between image quality and dose. Pediatr Radiol 2004;34:S183-95; discussion S234-41. [Crossref] [PubMed]
  32. Imajo K, Kessoku T, Honda Y, Tomeno W, Ogawa Y, Mawatari H, Fujita K, Yoneda M, Taguri M, Hyogo H, Sumida Y, Ono M, Eguchi Y, Inoue T, Yamanaka T, Wada K, Saito S, Nakajima A. Magnetic Resonance Imaging More Accurately Classifies Steatosis and Fibrosis in Patients With Nonalcoholic Fatty Liver Disease Than Transient Elastography. Gastroenterology 2016;150:626-637.e7. [Crossref] [PubMed]
  33. Park CC, Nguyen P, Hernandez C, Bettencourt R, Ramirez K, Fortney L, Hooker J, Sy E, Savides MT, Alquiraish MH, Valasek MA, Rizo E, Richards L, Brenner D, Sirlin CB, Loomba R. Magnetic Resonance Elastography vs Transient Elastography in Detection of Fibrosis and Noninvasive Measurement of Steatosis in Patients With Biopsy-Proven Nonalcoholic Fatty Liver Disease. Gastroenterology 2017;152:598-607.e2. [Crossref] [PubMed]
  34. Tang A, Desai A, Hamilton G, Wolfson T, Gamst A, Lam J, Clark L, Hooker J, Chavez T, Ang BD, Middleton MS, Peterson M, Loomba R, Sirlin CB. Accuracy of MR imaging-estimated proton density fat fraction for classification of dichotomized histologic steatosis grades in nonalcoholic fatty liver disease. Radiology 2015;274:416-25. [Crossref] [PubMed]
  35. Tang A, Tan J, Sun M, Hamilton G, Bydder M, Wolfson T, Gamst AC, Middleton M, Brunt EM, Loomba R, Lavine JE, Schwimmer JB, Sirlin CB. Nonalcoholic fatty liver disease: MR imaging of liver proton density fat fraction to assess hepatic steatosis. Radiology 2013;267:422-31. [Crossref] [PubMed]
  36. Lee SS, Lee Y, Kim N, Kim SW, Byun JH, Park SH, Lee MG, Ha HK. Hepatic fat quantification using chemical shift MR imaging and MR spectroscopy in the presence of hepatic iron deposition: validation in phantoms and in patients with chronic liver disease. J Magn Reson Imaging 2011;33:1390-8. [Crossref] [PubMed]
Cite this article as: Choi Y, Kim DK, Youn SY, Kim H, Choi JI. Unenhanced computed tomography for non-invasive diagnosis of hepatic steatosis with low tube potential protocol. Quant Imaging Med Surg 2022;12(2):1348-1358. doi: 10.21037/qims-21-474

Download Citation