The study protocol for the China Health Big Data (China Biobank) project
Original Article

The study protocol for the China Health Big Data (China Biobank) project

Yan Wu1#, Zhe Guo2#, Xiaoxia Fu3, Jing Wu4, Jianbo Gao1, Qiang Zeng5, Haihong Fu6, Xiaoguang Cheng2; for the China Health Big Data (China Biobank) project investigators

1Department of Radiology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China;2Department of Radiology, Beijing Jishuitan Hospital, Beijing 100035, China;3Editorial Office of the Chinese Health Management Journal, Beijing 100710, China;4National Center for Chronic and Noncommunicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 100050, China;5Health Management Institute, Chinese People’s Liberation Army General Hospital, Beijing 100853, China;6Department of Radiology, Beijing PUMC Hospital, Beijing 100730, China

#These authors contributed equally to this work.

Correspondence to: Dr. Xiaoguang Cheng. Department of Radiology, Beijing Jishuitan Hospital, Beijing, 100035, China. Email: xiao65@263.net; Dr. Qiang Zeng. Health Management Institute, Chinese People’s Liberation Army General Hospital, Beijing 100853, China. Email: zq301@126.com.

Background: Osteoporosis, obesity, and fatty liver are increasingly common chronic diseases that seriously threaten people’s health. Low-dose chest computed tomography (LDCT) scan is frequently used for lung cancer screening in health screenings and checkups. Quantitative computed tomography (QCT) enables the accurate measurement of volumetric bone mineral density (vBMD), liver fat content, and abdominal fat area using the existing LDCT data without extra radiation. We initiated a new project, the China Health Big Data (China Biobank), which combines the LDCT scan images from lung cancer screening of participants in health checkup with QCT to investigate the added value of QCT to LDCT, in order to establish the normative reference database and diagnosis criteria for the three aforementioned conditions.

Methods: The China Biobank project is a prospective nationwide multicenter cohort study that will combine QCT technology with LDCT scans to measure bone mineral density (BMD), intra-abdominal fat distribution, and liver fat content of the generally healthy checkup participants. Mindways QCT calibration phantom (Mindways Software Inc., Austin, TX, USA) and analysis software QCT PRO v6.0 will be used for all centers. Before data collection begins, the European Spine Phantom (ESP) will be used for quality control analysis at each collaborating center. The inclusion criteria are a healthy checkup participant aged 30–90 years, with LDCT as a part of his/her health checkup protocol. Exclusion criteria are pregnant women or participants with a metal implant in the CT scan area. The LDCT images will be transferred to the Mindways workstation for analysis, and vBMD in the L1 and L2 vertebrae, visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT), and liver fat content will be measured. As part of the health checkup, the demographic, anthropometric parameters, blood pressure, and a routine blood laboratory test will be collected. The estimated sample size will be about 30,000.

Results: The combination of QCT with LDCT of the chest was validated in this project. The vBMD of spine, visceral fat and liver fat can be measured with a LDCT chest scan.

Conclusions: The China Biobank project will assess the added value of QCT to LDCT, and enable accurate evaluation of the prevalence of osteoporosis, obesity, and fatty liver disease in a very large Chinese cohort.

Keywords: Osteoporosis; quantitative computed tomography (QCT); bone mineral density (BMD); liver fat content; soft tissue composition; visceral adipose tissue (VAT); subcutaneous adipose tissue (SAT)


Submitted Apr 20, 2019. Accepted for publication Jun 19, 2019.

doi: 10.21037/qims.2019.06.16


Introduction

With the improvement in living standards across China, the aging population, a more sedentary lifestyle, and the increased consumption of sugar and fat, obesity is becoming more common. The consequent health problems involve issues with multiple human organs and tissues, and osteoporosis, obesity, and non-alcoholic fatty liver disease (NAFLD) are now major public health concerns in China (1-4). Obesity is the cause of several serious diseases, and its diagnosis should be based on accurate measurements of the actual fat content in the human body, especially the excessive accumulation of abdominal visceral adipose tissue (VAT), which can lead to problems with lipid metabolism, hypertension, and blood glucose while accelerating the development of diabetes along with cardiovascular and cerebrovascular diseases (5). Similarly, NAFLD is an important cause of chronic liver disease that presents a significant economic burden on society (6).

The elderly population is a group with a high incidence of osteoporosis and its associated fragility fractures. Measurements of bone mineral density (BMD) play an important role in the diagnosis and prevention of osteoporosis, and there is an increasing appreciation of the value of measuring BMD using a quantitative computed tomography (QCT) (7-10). In the study of obesity, there is an increasing number of reports about the relationship between abdominal obesity and BMD. VAT is significantly negatively correlated with BMD, while measurements of subcutaneous adipose tissue (SAT) content are uncorrelated (11-13). QCT scans can also be used to make accurate measurements of liver fat. Therefore, there is now a focus on how to accurately monitor osteoporosis, obesity, and NAFLD in the general population. As a non-invasive three-dimensional (3D) imaging method, QCT has an important role to play in accurately measuring BMD, VAT, and liver fat content.

QCT provides a precise and accurate method of measuring BMD based on conventional computed tomography (CT) scanning using a calibration phantom and relevant scan analysis software that is now widely used in clinic (7,8,10,12-15). The associated lateral CT scout scans can also be used to identify and grade vertebral fractures, and hence find individuals with a history of fragility fracture. With the improvements in CT technology, advanced image reconstruction algorithms have now made extremely low-dose clinical applications possible, and the combination of low-dose scanning with QCT technology is an area undergoing continuous development (16-19). The application of low-dose chest CT (LDCT) in screening for early lung cancer has been widely recognized and applied (20), and has increased the detection rate of pulmonary nodules with diameter <10 mm (21). Without any increase in radiation dose, LDCT scan images can be combined with QCT technology to measure BMD in the L1 and L2 vertebrae, and also to accurately measure VAT and liver fat content at the mid-plain of the L2 using recently developed scan analysis applications (17,21).

Recently, we initiated a large scale nationwide multicenter study, the China Health Big Data (China Biobank) project, to use health checkup LDCT images acquired for lung cancer screening to measure the BMD, visceral fat, and liver fat content (Supplement I). The aim of the project is to establish a normal reference database of spine BMD, visceral fat, and liver fat content for the Chinese population, in order to further establish the QCT criteria for diagnosing osteoporosis, obesity, and NAFLD.


Methods

Study design

The China Biobank project is a prospective nationwide multicenter cohort study. The study has been approved by the ethics committees of our respective institutions and written informed consent will be obtained by the study participants. Trial registration: this program has been registered with the US clinical trials database (clinicaltrials.gov) (trial identifier: NCT03699228).

Setting

Each center is qualified to conduct medical examinations and is a licensed institution for CT diagnosis and treatment, equipped with at least a 16-slice CT scanner along with software for performing QCT (Mindways Software Inc., Austin, TX, USA). The clinical center in each collaborating hospital is certified by the Ministry of Health and guarantees that a certain number of LDCT scans are performed daily. Each center also has a hospital information system (HIS) that enables data export and sharing. The recruitment of the participating center is open and ongoing; currently, there are 16 centers that have been recruited.

Participants

The participants will be subjects >30 years old who have a LDCT scanning for lung cancer screening as part of his/her health checkup procedure. In China, the annual health checkup is benefit to each employee, and currently, the LDCT is only available for employees over 40 years old or senior employees. Usually, this selection depends on the age, without consideration for smoking or risk factors for lung cancer, and of course, the employee can choose not to undergo LDCT. The LDCT can also be selected with medical insurance coverage. For the younger subjects, radiation is more of a concern, extra caution was placed for a young person who wants to have a LDCT. Moreover, the rural residents and low-income population will be less represented in this project.

The current study will not intervene with a selection of LDCT of the subjects; this study only involves the added value of post-processing of existing LDCT raw data for BMD and fat measurement and for the screening of osteoporosis or obesity.

Inclusion/exclusion criteria

All existing LDCT raw data of the health check-up subjects will be included for further QCT analysis for BMD and fat measurement. The exclusion criteria for LCDT data are the following: (I) from subjects younger than 30 years old; (II) from subjects with metal implants within the upper abdominal scan area.

Sample size estimation

LDCT screening for lung cancer is a frequently performed examination in China. This project will continue for 2 years in the 16 collaborating centers (Supplement I), and the total sample size is anticipated to reach about 50,000 participants. The establishment of such a large data sample will aid future research and follow-up.

Conduct of the project

This project only involves the post-imaging process of existing LDCT image data for adding value for BMD and fat measurement, and thus, no extra radiation is involved. The primary goal is to investigate the normal BMD reference and the prevalence of osteoporosis across China with QCT. The secondary goal is to investigate the normal reference of visceral fat and liver fat in the Chinese population and its association with body mass index (BMI). Potential subjects meeting the above criteria who give written informed consent will receive a routine health check-up procedure and a brief introduction to the project. Healthy subjects who consent to participate and meet the required inclusion and exclusion criteria will be enrolled for anthropometric and clinical assessments, blood analysis, and QCT analysis of their LDCT images (Table 1). Smoking and alcohol use are collected in some, but not all centers. As explained earlier, in this health checkup procedure, the selection of an LDCT depends mostly on age, not on smoking status; even though the history of smoking is collected in some centers, therefore the smoker or alcohol user is not over sampled in this project.

Table 1
Table 1 The main parameters to be collected in this project
Full table

Blood sampling and methods of analysis

The blood sampling and laboratory analysis are parts of the health checkup procedure, and this project will only retrieve these results for further analysis. Venous blood samples will be taken by a registered staff nurse between 7.30 and 9.30 am and will be sent for laboratory analysis within 30 minutes. Participants will be asked to fast for at least 8 hours overnight before venipuncture. All tests and analyses will be conducted in a certified clinical examination center at each of the collaborating medical centers.

Anthropometry and blood pressure measurement

Weight (kg) and height (m) will be measured using calibrated digital weighing scales and stadiometers. BMI will be calculated from the following formula: weight (kg)/height2 (m2). Abdominal circumference (an optional item) will be measured using a measurement tape at the level of the belly button.

Chest CT scanning and QCT quality control analysis

QCT measurements will be made from existing chest CT scan image data. Image reconstruction with a range from the diaphragm roof to the lower edge of the L2 is based on a standard Fourier back projection algorithm. The operators are all qualified technologists, with strict adherence to the relevant radiation protection requirements. Before commencement of any data collection, the European Spine Phantom (ESP No. 145) will be used for quality control analysis at each collaborating center based on 10 repeated scans acquired following a prescribed QCT scanning protocol. The collaborating centers will archive the reconstructed images in DICOM and QCT formats.

Data analysis

QCT analysis will be performed by professionally trained medical personnel with the relevant qualifications.

BMD measurement procedure

(i) The reconstructed CT images will transferred to the QCT workstation and the subject’s information will be verified; (ii) the L1 and L2 vertebrae will be identified (Figure 1), scan analysis will be performed according to the Mindways QCT-PRO operator’s manual, and the results will be transferred to the database; (iii) if the L1 or L2 vertebrae are found to be fractured or have other lesions on the CT images, the BMD measurements will be omitted and a note made in the database.

Figure 1 QCT measurement of L1 (A) and L2 (B) lumbar spine BMD. The dual-yellow lines indicate the location and upper and lower range of interest (region of interest, ROI), the yellow oval ROIs show the measurement range of vertebral, and the BMD unit is mg/cm3. QCT, quantitative computed tomography; BMD, bone mineral density.

Measurement of abdominal fat

(i) Measurement of VAT will be conducted using the Supplementary Tissue Measurements application of the Mindways QCT-PRO v6.0 spine module software; (ii) the mid-slice of the L2 vertebra will be selected and measured according to the QCT-PRO operator’s manual, and the total abdominal fat and the VAT measurements will be obtained; (iii) SAT at the same level will be obtained by subtracting VAT from the total abdominal fat (Figure 2), and the results will be transferred to the database; (iv) if it is found that CT images cannot be used to measure abdominal fat, this will be noted in the database.

Figure 2 Measurement of abdominal fat by Mindways QCT software. The blue color represents the fat, and the yellow dashed line depicts the abdominal wall. The fat inside this wall is visceral fat (VAT), while the fat outside the wall is subcutaneous fat (SAT). Total fat area (TAT) = VAT + SAT. QCT, quantitative computed tomography.

The QCT-PRO scan analysis software uses the threshold segmentation method to mark the total abdominal fat in the scan plane in blue (Figure 2). By automatically outlining the outer edge of the abdominal wall muscle (the green closed curve in Figure 2), the total fat is divided into the visceral fat area (the fat area within the green closed curve) and the subcutaneous fat area (the fat area outside the green curve). Both measurements are in units of cm2.

Measurement of liver fat content

QCT quantification of liver fat content will be performed using the Supplementary Tissue Measurements application of the Mindways QCT-PRO v6.0 spine module scan analysis software as described by Cheng et al. (22). The slice where the right branch of the portal vein enters the liver will be chosen for the measurement. Three circular regions of interest (ROI) each with a cross-sectional area 300 mm2 (deviation <10 mm2) will be placed in the left lobe and the anterior and posterior segments of the right lobe respectively (Figure 3). The ROIs will be placed in the subcapsular region of the liver, avoiding the bile duct and blood vessels. If the left lobe of the liver is too small to be visible in this slice, the slice in which the left lobe had the largest area will be used for the measurement.

Figure 3 Measurement of liver fat content by QCT using Mindways liver fat module. The slice in the middle of the L2 is chosen, 3 region of interests (ROIs) (shown in red circle) are measured, with one in the left robe of the liver (A) and two in the right lobe (B,C). The liver fat content in % is shown and saved in the database. The average of 3 ROIs is the value for this subject. QCT, quantitative computed tomography.

Data collection of physical examination population

The basic health information of the physical examination population will be retrieved from the HIS system of each collaborating center, including the name, gender, age, height, weight, abdominal circumference, blood pressure, blood routine, and blood biochemical examination results.


Discussion

Bone density measurements are the internationally accepted basis for the diagnosis of osteoporosis. In the clinic, there are two widely adopted methods, dual-energy X-ray absorptiometry (DXA) and QCT. While DXA is a two-dimensional (2D) projection scan that measures areal BMD, QCT provides a true 3D BMD measurement, and, compared with DXA, is less affected by severe degeneration of the spine, vascular calcification, oral contrast agent, and body position. Therefore, QCT is receiving wider recognition as the more accurate method for the quantitative evaluation of osteoporosis.

The International Society for Clinical Densitometry (ISCD) and American College of Radiology (ACR) has the following recommendations for the diagnosis of osteoporosis using QCT: osteoporosis, BMD <80 mg/cm3); osteopenia, BMD 80–120 mg/cm3; and normal, BMD >120 mg/cm3) (23,24). In the present protocol, we will measure the 1st and 2nd lumbar vertebrae, select the mid-plain of each vertebra, calculate the BMD, and take the average of the two vertebrae.

The excess visceral fat area can lead to disorders of lipid metabolism, hypertension, or blood glucose, and accelerate the development of cardiovascular and cerebrovascular diseases (6,25). Currently, the CT diagnostic criteria adopted in Japan for the diagnosis of intra-abdominal obesity is a visceral fat area at the level of the belly button >100 cm2 (26,27), while at present there is a lack of a unified diagnostic standard in China. In previous studies, the level of the belly button or the level of the L4 and L5 vertebrae were measured, and several new studies have shown that measurements at the level of the L2 and L3 are better correlated with the total fat area (28). There is presently no unified standard for the measurement of VAT at the level of the L2 vertebra, and this project aims to establish a reference standard for the diagnosis of intra-abdominal obesity in China.

There are a few limitations for this project. First, this project only includes the health check-up population with LDCT available; this project thus does not represent the general population of China; the rural residents/farmers and low-income populations, for instance, will be under-represented. Secondly, LDCT with health checkups is common in most parts of China, but less common in north-west China, which will, therefore, be less sampled.

In summary, the aim of this project is to combine QCT technology with LDCT to measure the BMD, VAT, and liver fat content in a large Chinese checkup cohort for the purpose of investigating the added value of QCT to existing LDCT data for health management. This will provide the normative reference database of spinal BMD, visceral fat area, and liver fat content, establish diagnosis criteria and survey the prevalence of osteoporosis, obesity, and steatosis.


Supplementary

Supplement I

The China Health Big Data (China Biobank) project collaborators

PI, Dr. Xiaoguang Cheng, Department of Radiology Beijing Jishuitan Hospital, Beijing, China; Co-PI, Dr. Qiang Zeng, Health Management Institute of PLA General Hospital, Beijing, China; Co-PI, Ms. Xiaoxia Fu, Editorial Office, Chinese Journal of Health Management, Beijing, China; Co-PI, Yuanzheng Ma, 309 Hospital, Beijing, China; Co-PI, Jing Wu, The Chronic Non-communicable Disease Control Center of China Disease Control and Prevention Center, Beijing, China; Quality Control and Data Center: Xiaoguang Cheng. Beijing Jishuitan Hospital, Beijing, China; Data Management: Kaiping Zhao, Beijing Jishuitan Hospital, Beijing, China.

Participating centers

Northeastern China
  • The First Affiliated Hospital of Harbin Medical University, Harbin (Dr. Xigang, Xiao, Sub PI);
  • The First Affiliated Hospital of China Medical University, Shenyang (Dr. Songbai, Li, Sub PI).
Northern China
  • The China-Japan Friendship Hospital, Beijing (Dr. Xiao Ma, Sub PI).
Northwestern China
  • The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an (Dr. Mao, Ma, Sub PI).
Eastern China
  • The Affiliated Huashan Hospital of Fudan University, Shanghai (Dr. Shuang Chen, Sub PI);
  • The Affiliated Ruijin Hospital of Shanghai Jiaotong University Medical College, Shanghai (Dr. Yong Lu, Sub PI);
  • The Affiliated Yijishan Hospital of Wannan Medical University, Wuhu (Dr. Xiaojuan, Zha, Sub PI);
  • The People’s Hospital of Zhengjiang Province, Hangzhou (Dr. Xiongyang, Gong, Sub PI);
  • The Eastern Lihuili Hospital, Ningbo (Dr. Yuqing, Zhang, Sub PI)
Southern China
  • The Sun Yat-sen Memorial Hospital of Sun Yat-Sen University, Guangzhou, (Dr. Jun, Shen, Sub PI);
  • The Fifth Affiliated Hospital of Sun Yat-Sen University, Zhuhai (Dr. Shaolin, Li, Sub PI).
Southwestern China
  • The Affiliated Hospital of Guiyang Medical University, Guiyang (Dr. Jun, Jiao, Sub PI);
  • The First Affiliated Hospital of Chongqing Medical University, Chongqing (Dr. Haitao, Yang, Sub PI).
Central China
  • The People’s Hospital of Henan Province, Zhengzhou (Dr. Yongli, Li, Sub PI);
  • The First Affiliated Hospital of Zhengzhou University, Zhengzhou (Dr. Yan, Wu, Sub PI);
  • The People’s Hospital of Wuhan University, Wuhan, (Dr. Yunfei, Zha, Sub PI).

Acknowledgments

Funding: This work is supported by the Beijing Natural Science Foundation-Haidian Primitive Innovation Joint Fund (grant no. L172019) and by the grants from the Beijing Bureau of 215 Program (No. 2013-3-033; 2009-02-03).


Footnote

Conflicts of Interest: The authors have no conflicts of interest to declare.

Ethical Statement: The study has been approved by the ethics committees of our respective institutions and written informed consent will be obtained by the study participants.


References

  1. Zhang ZL, Jin XL, Xia WB. Interpretation of the Key Points of Diagnosis and Treatment Guidelines for Primary Osteoporosis (2017 Edition). Chinese Journal of Osteoporosis and Bone Mineral Research 2017;10:411-2.
  2. Consensus development conference. diagnosis, prophylaxis, and treatment of osteoporosis. Am J Med 1993;94:646-50. [Crossref] [PubMed]
  3. Rosito GA, Massaro JM, Hoffmann U, Ruberg FL, Mahabadi AA, Vasan RS, O'Donnell CJ, Fox CS. Pericardial fat, visceral abdominal fat, cardiovascular disease risk factors, and vascular calcification in a community-based sample: the Framingham Heart Study. Circulation 2008;117:605-13. [Crossref] [PubMed]
  4. Hayashi T, Boyko EJ, Leonetti DL, McNeely MJ, Newell-Morris L, Kahn SE, Fujimoto WY. Visceral adiposity is an independent predictor of incident hypertension in Japanese Americans. Ann Intern Med 2004;140:992-1000. [Crossref] [PubMed]
  5. Lovren F, Teoh H, Verma S. Obesity and atherosclerosis: Mechanistic insights. Can J Cardiol 2015;31:177-83. [Crossref] [PubMed]
  6. Fan JG, Farrell GC. Epidemiology of alcoholic and nonalcoholic fatty liver disease in China. J Gastroenterol Hepatol 2013;28 Suppl 1:11-7. [Crossref] [PubMed]
  7. Zhang XD, Zhao WJ, Chen YJ, Zhao YX, Hu SY, Yan JW, Zhao J, Li SL. Correlation of Lumbar Bone Mineral Density with Age, Gender, Physical Parameters and Abdominal Fat. Chinese Journal of Medical Imaging Technology 2015;31:762-5.
  8. Dai YL, Zhao Y, Liu WY, Yang W, Ma H, Zhao JQ. Correlation Analysis of Lumbar Bone Mineral Density, Age and Paravertebral Body Composition in Elderly Women. Chinese Journal of Osteoporosis 2014;20:597-601.
  9. Lu ZK, Wang GM, Tian ZL, Zhang SF, Liu GY, Qiao Y, Wang YR. CT Quantitative analysis of lumbar Bone Mineral Density and Its Related Factors in Chronic Obstructive Pulmonary Disease. Chinese Remedies & Clinics 2014;14:48-50.
  10. Li N, Li XM, Sun WJ, Cheng XG, Jiang XX. Comparative Analysis of the Detection Rate of Osteoporosis in Elderly Patients by Quantitative Lumbar CT and Dual-energy X-ray Bone Mineral Density Measurement. Chinese Journal of Osteoporosis and Bone Mineral Research 2012;5:87-92.
  11. Russell M, Mendes N, Miller KK, Rosen CJ, Lee H, Klibanski A, Misra M. Visceral fat is a negative predictor of bone density measures in obese adolescent girls. J Clin Endocrinol Metab 2010;95:1247-55. [Crossref] [PubMed]
  12. Gilsanz V, Chalfant J, Mo AO, Lee DC, Dorey FJ, Mittelman SD. Reciprocal relations of subcutaneous and visceral fat to bone structure and strength. J Clin Endocrinol Metab 2009;94:3387-93. [Crossref] [PubMed]
  13. Choi HS, Kim KJ, Kim KM, Hur NW, Rhee Y, Han DS, Lee EJ, Lim SK. Relationship between visceral adiposity and bone mineral density in Korean adults. Calcif Tissue Int 2010;87:218-25. [Crossref] [PubMed]
  14. Cheng XG, Yu W. Development and Clinical Application of Quantitative CT Bone Mineral Density Measurement Technology. Chinese Journal of Medical Imaging 2011;19:881-3.
  15. Cheng XG, Yu AH, Yu W, Li SL, Cha YF. Imaging Evaluation of Bone Health. Chinese Journal of Medical Imaging Technology 2015;31:1451-3.
  16. Engelke K. Quantitative Computed Tomography-Current Status and New Developments. J Clin Densitom 2017;20:309-21. [Crossref] [PubMed]
  17. Wu Y, Jiang Y, Han X, Wang M, Gao J. Application of low-tube current with iterative model reconstruction on Philips Brilliance iCT Elite FHD in the accuracy of spinal QCT using a European spine phantom. Quant Imaging Med Surg 2018;8:32-8. [Crossref] [PubMed]
  18. Link TM, Lang TF. Axial QCT: clinical applications and new developments. J Clin Densitom 2014;17:438-48. [Crossref] [PubMed]
  19. Jiang YJ, Wu Y, Zhang YG, Dong JQ, Liu J, Hou P, Gao JB. Application Value of Low-tube Current Combined with Multi-model Iterative Reconstruction Technology for the Accuracy of Quantitative CT of Lumbar Spine. Chinese Journal of Radiological Medicine and Protection 2018;38:59-63.
  20. Hu Y, Fang J, Deng DB, Liang MJ, Zhou Q. Research progress of Lung Cancer Screening with Low-dose Chest CT. Chinese Journal of Medical Imaging Technology 2015;31:146-9.
  21. Jiang YJ, Wu Y, Zhang YG, Dong JQ, Liu J, Hou P, Gao JB. Effect of Low-tube Current Combined with Iterative Reconstruction Algorithm on the Accuracy of Bone Mineral Density of Chest Model T12 and Chest Image Quality. Chinese Journal of Medical Imaging Technology 2018;34:429-33.
  22. Cheng X, Blake GM, Brown JK, Guo Z, Xu L. The measurement of liver fat from single-energy quantitative computed tomography scans. Quant Imaging Med Surg 2017;7:281. [Crossref] [PubMed]
  23. Engelke K, Adams JE, Armbrecht G, Augat P, Bogado CE, Bouxsein ML, Felsenberg D, Ito M, Prevrhal S, Hans DB, Lewiecki EM. Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: the 2007 ISCD Official Positions. J Clin Densitom 2008;11:123-62. [Crossref] [PubMed]
  24. American College of Radiology. ACR–SPR–SSR practice parameter for the performance of musculoskeletal quantitative computed tomography (QCT) 2018. Available online: https://www.acr.org/-/media/ACR/Files/Practice-Parameters/QCT.pdf
  25. Kuk JL, Church TS, Blair SN, Ross R. Does measurement site for visceral and abdominal subcutaneous adipose tissue alter associations with the metabolic syndrome? Diabetes Care 2006;29:679-84. [Crossref] [PubMed]
  26. Ryo M, Kishida K, Nakamura T, Yoshizumi T, Shimomura I. Clinical significance of visceral adiposity assessed by computed tomography: A Japanese perspective. World J Radiol 2014;6:409-16. [Crossref] [PubMed]
  27. Bao Y, Lu J, Wang C, Yang M, Li H, Zhang X, Zhu J, Lu H, Jia W, Xiang K. Optimal waist circumference cutoffs for abdominal obesity in Chinese. Atherosclerosis 2008;201:378-84. [Crossref] [PubMed]
  28. Cheng X, Zhang Y, Wang C, Deng W, Wang L, Duanmu Y, Li K, Yan D, Xu L, Wu C, Shen W, Tian W. The optimal anatomic site for a single slice to estimate the total volume of visceral adipose tissue by using the quantitative computed tomography (QCT) in Chinese population. Eur J Clin Nutr 2018;72:1567-75. [Crossref] [PubMed]
Cite this article as: Wu Y, Guo Z, Fu X, Wu J, Gao J, Zeng Q, Fu H, Cheng X; for the China Health Big Data (China Biobank) project investigators. The study protocol for the China Health Big Data (China Biobank) project. Quant Imaging Med Surg 2019;9(6):1095-1102. doi: 10.21037/qims.2019.06.16

Download Citation